Ram preventers are designed for wellhead sealing during drilling, lowering and retrieval of tubing and other well completion and workover operations.

Depending on the need, operating conditions, ram preventers can be single or double. This provides a variety of designs and the most rational use of space for operation and maintenance. Preventers are equipped with blind pipe or cutting rams. Preventers are operated both manually and hydraulically.

  • Preventer operation – hydraulic (manual)
  • meets technical requirements API 16A
  • Nominal size, mm (in): 180-430 (7 1/16-16 3/4)
  • Work pressure, MPa (PSI): 35-105 (5000-15000)
  • Service environment: oil, gas, solution, water
  • Work temperature, °С: from -60 to +121
  • Material class: АА, ВВ, СС, DD, ЕЕ, FF, НН

Specifications

Type Nominal size Work pressure (MPa/PSI)
mm in 35 (5000) 70 (10000) 105 (15000)
1 SPH  180 180 7 1/16 + + +
2 SPH 230 230 9 + + +
3 SPH 280 280 11 + + +
4 SPH 350 350 13 5/8 + + +
5 SPH 430 430 16 3/4 + +