The valve is designed to launch drill pumps in conditions that ensure no load on the drive motors, and to smoothly restore fluid circulation in the well. Operation – remote pneumatic. The top outlet is designed for connection with manifold. The drain pipe is connected to the bottom outlet.
Specifications
| Characteristics | Unit | TLD 3600 | TLD 5000 | TLD 5700 |
| Work pressure, up to | MPa | 25 | 32 | 40 |
| Test pressure, up to | MPa | 37.5 | 48 | 60 |
| Nominal size diameter, not less | mm | 40 | 40 | 40 |
| Pressure in the pneumatic unit , up to | MPa | 0.6÷0.8 | 0.6÷0.8 | 0.6÷0.8 |
| Service environment | – | Water-based or water-carbon based drilling mud up to 2.2 g/cm3 weighted with barite or hematite | ||
| Service environment temperature | °С | from 0 to +40 | from 0 to +40 | from 0 to +40 |
| Dimensions, mm, up to | ||||
| – length | mm | 350 | 350 | 350 |
| – width | mm | 385 | 530 | 520 |
| – height | mm | 510 | 490 | 445 |
| Weight, up to | kg | 78 | 84 | 102 |